Building glass is in the list of building materials products, one of seven groups of building materials products issued by the Ministry of Construction, Circular 19/2019/TT-BXD.
In particular, IFIC is one of the first units appointed by the Ministry of Construction to carry out the assessment and certification of 7 groups of building materials under QCVN 16:2019/BXD. In QCVN 16:2019/BXD, the product group that needs to be certified and declared conformity is added to include the group of construction glass, this circular takes effect from 01/07/2020.
1. Issuance of building glass conformity certification:
Building glass is all kinds of glass products used and installed in construction works. Moreover, this is a group of products that can cause high unsafety. Therefore, the certification of construction glass conformity is extremely necessary.
There are 4 types of building glass that need to be certified and announced:
- Float glass
- Heat tempered flat glass
- Laminated glass and laminated safety glass
- Insulated sealed box glass
Building glass must be tested to specifications according to the respective test methods and must satisfy the following specified requirements:
Bảng 1 – List of products, goods and building materials group 2
No | Product’s name | Required Levels and Test Methods | Code of export and import goods (HS) | |||
1 | Float glass | According to Appendix L | 7005.29.90 | |||
2 | Heat tempered flat glass | 7007.19.90 | ||||
According to Appendix M | ||||||
3 | Laminated glass and laminated safety glass | 1. Thickness deviation | TCVN 7364-2:2018 | TCVN 7219:2018 | 3 samples, size >= 610×610 mm | 7007.29.90 |
2. Appearance defects | TCVN 7364-4:2018 | 6 samples, size >= 100×300 mm | ||||
3. Heat resistance | ||||||
4 | Insulated sealed box glass | 1. Nominal Thickness | Permissible deviation* | TCVN 8260:2009 | 6 samples size 350x500mm | 7008.00.00 |
Less than 17 | ± 1,0 | |||||
From 17 to 22 | ± 1,5 | |||||
Greater than 22 | ± 2,0 | |||||
2. Appearance defects | No stains, stains of different colors, glued plastic… are allowed on the surface of the product. | |||||
3. Dew point, not higher | ||||||
(*) For insulated sealed box glazing with two or more layers of gas and a thickness of one gas layer greater than or equal to 15 mm, the difference in thickness shall be agreed between the parties concerned. |
3. Purpose of building glass conformity certification::
Products and goods of construction materials specified in Table 1, Part 2 of this Regulation, when circulating on the market, must have a certificate of conformity, a notice of conformity and/or a notice of receipt of the application. regulation conformity announcement of the Department of Construction of the province or centrally run city where the organization or individual has registered their business.
– Help products meet legal requirements when put on the market.
– Increase competitive advantage, expand market share of products in the market.
2. Test methods of building glass:
The certification of conformity for products and goods of building materials mentioned in Table 1, Part 2 of this Regulation shall be carried out according to the following methods: mode 1, mode 5, mode 7 specified in this Circular. No. 28/2012/TT-BKHCN dated December 12, 2012 of the Ministry of Science and Technology, providing for announcement of standard conformity, announcement of regulation conformity and methods of assessment of conformity with standards, technical regulations and standards. Circular No. 02/2017/TT-BKHCN dated March 31, 2017 of the Minister of Science and Technology amending and supplementing a number of articles of Circular No. 28/2012/TT-BKHCN, specifically as follows:
- Method 1: Typical sample test. The validity of the Certificate of Conformity is 1 year and is monitored through testing of samples each time it is imported. The certificate of conformity is only valid for the type and type of products and goods being sampled for testing. This method applies to imported products manufactured by overseas production facilities that have built a quality management system according to ISO 9001 or equivalent;
- Mode 5: Testing of typical samples and evaluation of the production process; monitoring through testing of samples taken at the production site or on the market in conjunction with assessment of the production process. The validity of the Certificate of Conformity is not more than 3 years and is monitored annually through testing of samples at the production site or on the market in combination with the assessment of the production process. This method applies to products manufactured by domestic or foreign manufacturers that have established and maintained a stable quality management system, conditions to ensure the production process according to standards. ISO 9001 or equivalent;
- Method 7: Testing and evaluating batches of products and goods. The validity of the Certificate of conformity is only valid for batches of products and goods.
Customers who do not know how to choose a suitable, cost-effective and business-effective method, please call 0789123102 immediately for support.
IFIC PROVIDE OPTIMAL SOLUTIONS FOR CUSTOMERSG
- IFIC is designated by the Ministry of Construction as an organization certifying conformity of building materials products according to QCVN 16:2019/BXD (See designation xxx/QD-BXD of the Ministry of Construction here).
- Issuing construction materials conformity certification nationwide with the headquarters in Ho Chi Minh City helps customers easily access and save time and travel costs as well as easily support and meet customers face-to-face when needed.
- IFIC has granted certificates of conformity of construction materials to partners such as Interlog, TV.WINDOW, Quan Dat, Vinalink, NP Tech and many major partners, customers manufacturing and importing construction materials nationwide.c.
- Owns a laboratory for construction materials and inspection (Building materials code LAS-XD 1xxx) specializing in the field of construction materials, which is well-invested, modern technology meets the standards of the Ministry of Construction.
- Experimenting with all costs of Mechanics at the headquarters helps to cut costs and get the best price for customers.
EFFECTIVE
- The service fee is flexible according to the needs and solutions that customers choose after being supported by IFIC. Ensure reasonable criteria (according to needs, size and current status of the business) – the most competitive in the market.
- There is a fast analytical test service to meet the urgent requirements of customers.
- Service costs are disclosed and transparent (no other costs are incurred), the contract contents are clear, and are specifically notified to the customer before signing.
- Ensure that products not only obtain certification but are also declared valid and safe when circulating on domestic and foreign markets.
- Commitment on schedule, business security of all organizations and businesses.
SUPPORT
- Support, guide and answer all difficulties and obstacles from customers completely free of charge.
- A team of seasoned professionals with industry certifications, professional and technical knowledge, rich experience in evaluating and providing appropriate solutions, is always dedicated to customers.
FILE
- Quick entry procedures, simplifying processes, records and tasks from customers.
- Committed to issuing the certificate of conformity as quickly as possible (by optimizing the working process at the company, minimizing the time delay in the certification activities to ensure that the enterprise receives the certificate) fastest and fully compliant with certification standards and processes)
- The process is fast, with results within 3 days or within 24 hours if the regulations allow. (Owning a laboratory meeting BXD standards)
- Delivery of certificates to customers.
- Post-certification publication guidance and support.
Customers who need to issue a certificate of conformity for concrete bricks, please contact hotline 0789123102 for advice and a completely free quote.